Difference between revisions of "Raid"
(→kopieer partities over volgende drives) |
(→kopieer partities over volgende drives) |
||
Line 38: | Line 38: | ||
# mdadm --add /dev/md0 /dev/hdc1 |
# mdadm --add /dev/md0 /dev/hdc1 |
||
− | = |
+ | = Toevoegen drives = |
+ | Voeg aan een bestaande raid5 configuratie met twee drives twee extra drives toe. Dit gaat in stappen: |
||
+ | * Kopieer de partitie tabel van de tweed drive naar drives drie en vier |
||
+ | * Voeg de relevante partities van beide drives als spare toe |
||
+ | * Breid het aantal devices van de array uit |
||
+ | * Breid het physical volume van de array uit |
||
+ | == Kopieer partities over volgende drives == |
||
De beste manier om identieke partities op raid devices te maken is het kopieren van de partitie tabel over de volgende disk heen: |
De beste manier om identieke partities op raid devices te maken is het kopieren van de partitie tabel over de volgende disk heen: |
||
sfdisk -d /dev/sda | sfdisk /dev/sdb |
sfdisk -d /dev/sda | sfdisk /dev/sdb |
||
+ | Dit gaat niet altijd zonder slag of stoot, zeker als je drives van verschillende merken in de array hebt. In dat geval is het noodzakelijk om de partitietabel handmatig toe te voegen. |
||
− | mdadm -a /dev/md0 /dev/sdb3 /dev/sdd3 |
||
+ | == Uitbreiden van de array == |
||
− | mdadm --grow --raid-devices=4 /dev/md0 |
||
+ | Het uitbreiden van de array gaat door eerst spares toe te voegen en daarna de array met de spares uit te breiden |
||
− | 623 watch cat /proc/mdstat |
||
+ | <pre> |
||
− | 624 pvscan |
||
− | + | mdadm -a /dev/md0 /dev/sdb3 /dev/sdd3 |
|
− | + | mdadm -a /dev/md1 /dev/sdb4 /dev/sdd4 |
|
+ | mdadm --grow --raid-devices=4 /dev/md0 |
||
− | 627 pvscan |
||
+ | mdadm --grow --raid-devices=4 /dev/md1 |
||
+ | </pre> |
||
+ | Volg het proces met |
||
+ | watch cat /proc/mdstat |
||
+ | Aan het einde van het proces laat de array de nieuwe omvang zien met |
||
+ | <pre> |
||
+ | mdadm --detail /dev/md0 |
||
+ | mdadm --detail /dev/md1 |
||
+ | </pre> |
||
+ | De nieuwe extra ruimte is nog niet beschikbaar voor het op physical volume op de array |
||
+ | <pre> |
||
+ | pvscan |
||
628 pvresize /dev/md1 |
628 pvresize /dev/md1 |
||
629 pvscan |
629 pvscan |
||
+ | </pre> |
||
− | |||
== lvm op een software raid == |
== lvm op een software raid == |
||
Na de installatie van nuttige software: |
Na de installatie van nuttige software: |
Revision as of 09:12, 21 November 2012
Contents
Software matige RAID
Configureer de Raid voor de dom0 tijdens de installatie van de fysieke host.
De dom0 server zelf
Een een softwarematige RAID bestaat op een dom0 uit meerdere md-devices. Creeer het eerste kleine device 8Gb - 20Gb tijdens de installatie volgens deze stappen:
- in the following menu, scroll to your first disk and hit enter: the partitionier asks you, if you want to create an empty partition table. Say "yes". (Hint: this will erase your existing data, if any.)
- The partitioner is back in the disk overview, scroll one line downwards over the line with "FREE SPACE" and hit enter.
- Create a partition with the size you need, but remember the size and the logical type.
- In the "Partition settings" menu, go to "Use as" and hit enter.
- Change the type to "physical volume for RAID".
- Finish this partition with "Done setting up the partition".
- Create other partitions on the same disk, if you like.
- Now repeat all the steps from the first disk for the second disk.
After this, you should have at least two disks with the same partition schema and all partitions (beside swap) should be marked for RAID use.
- Now look at the first menu entry in the partitioner menu, there is a new line: "Configure software RAID". Go into this menu.
- Answer the question, if you like to write the changes, with "Yes".
- Now pick "Create MD device".
- Use RAID1 and give the number of active and spare devices (2 and 0 in our case).
- In the following menu, select the same device number on the first and second disk and Continue.
Repeat this step for every two devices until you are done. Then use "Finish" from the Multidisk configuration options.
You are back in the partitioner menu and now you see one ore more new partitions named as "Software RAID Device". You can use this partitions like any normal partition and continue installing your system.
Meer info op : http://www.howtoforge.com/software-raid1-grub-boot-debian-etch
5.2.4. Managing RAID devices (RAID-1 and up!!) Setting a disk faulty/failed:
- mdadm --fail /dev/md0 /dev/hdc1
[Caution] DO NOT run this every on a raid0 or linear device or your data is toasted! Removing a faulty disk from an array:
- mdadm --remove /dev/md0 /dev/hdc1
Clearing any previous raid info on a disk (eg. reusing a disk from another decommissioned raid array)
- mdadm --zero-superblock /dev/hdc1
Adding a disk to an array
- mdadm --add /dev/md0 /dev/hdc1
Toevoegen drives
Voeg aan een bestaande raid5 configuratie met twee drives twee extra drives toe. Dit gaat in stappen:
- Kopieer de partitie tabel van de tweed drive naar drives drie en vier
- Voeg de relevante partities van beide drives als spare toe
- Breid het aantal devices van de array uit
- Breid het physical volume van de array uit
Kopieer partities over volgende drives
De beste manier om identieke partities op raid devices te maken is het kopieren van de partitie tabel over de volgende disk heen:
sfdisk -d /dev/sda | sfdisk /dev/sdb
Dit gaat niet altijd zonder slag of stoot, zeker als je drives van verschillende merken in de array hebt. In dat geval is het noodzakelijk om de partitietabel handmatig toe te voegen.
Uitbreiden van de array
Het uitbreiden van de array gaat door eerst spares toe te voegen en daarna de array met de spares uit te breiden
mdadm -a /dev/md0 /dev/sdb3 /dev/sdd3 mdadm -a /dev/md1 /dev/sdb4 /dev/sdd4 mdadm --grow --raid-devices=4 /dev/md0 mdadm --grow --raid-devices=4 /dev/md1
Volg het proces met
watch cat /proc/mdstat
Aan het einde van het proces laat de array de nieuwe omvang zien met
mdadm --detail /dev/md0 mdadm --detail /dev/md1
De nieuwe extra ruimte is nog niet beschikbaar voor het op physical volume op de array
pvscan 628 pvresize /dev/md1 629 pvscan
lvm op een software raid
Na de installatie van nuttige software:
root@host:~# apt-get install mdadm raidutils array-info
Configuratie van een nieuw md-device:
root@host:~# cat /proc/mdstat root@host:~# mdadm -v --create /dev/md0 --level=raid5 --raid-devices=2 /dev/sda5 /dev/sdb5
Volg het proces met:
root@host:~# watch cat /proc/mdstat
root@host:~# pvcreate /dev/md0 root@host:~# pvscan root@host:~# array-info -v -d /dev/md0 root@host:~# pvdisplay root@host:~# vgcreate kvm-root /dev/md0
Volg hierna de normale procedure voor het bouwen van een domU.